Vapor Liquid Vertical Separator Sizing
CheCalc.com
Vapor Liquid Vertical Separator does the Design sizing and calculation for a vertical gas liquid separator with or without Mesh Pad based on Souders Brown Equation. K Values can be estimated based on GPSA method, Droplet Size and on user input.
Vapor
Mass flowrate
Kg/hr
Density
Kg/m
3
Liquid
Mass flowrate
Kg/hr
Density
Kg/m
3
Residence Time
NLL to LLL
min
HLL to NLL
min
K Value
Select
GPSA
Droplet Size
User Input
Pressure
Bar G
Requirement
No Special Requirement
Glycol or Amine Solution
Compressor Suction Scrubber
Expander Inlet Separators
Without Mesh Pad
Mesh Pad
With Mesh Pad
Without Mesh Pad
Viscosity
(Vapor)
cP
Droplet Size
Micron
K-Value
ft/s
Terminal Vel.
(Vt)
ft/s
56
Design Velocity
% of Vt
Nozzle Sizing
Feed In, ρV
2
Kg/m.s
2
Vapor Out, ρV
2
Kg/m.s
2
Liquid Out, V
Max.
m/s
L/D Ratio
L/D Required
Design Based on
English Units
Metric Units
Mass Flowrate
lb/h
Kg/h
lb/s
Kg/s
Density
lb/ft3
Kg/m3
g/cm3
lb/in3
Pressure
Kg/cm2 G
Kg/cm2 A
Bar G
Bar A
PSIG
PSIA
Atm G
Atm Abs
KPaG
KPa Abs
Velocity
ft/s
m/s
ρV
2
lb/ft.s2
Kg/m.s2
Data
Result
Units
How to Use
|
Solved Examples
Home
» Vapor Liquid Vertical Separator