Solved Examples
Steam Condensate available at 150 PSIG is to be flashed to a lower pressure of 15 PSIG. Condensate Flowrate is 10,000 lb/hr, Calculate
amount of Vapor and Liquid generated on flashing.
- Select Calculation Tab.
- Input required data as stated above in Yellow Highlighted Cells
- Calculator will provide following result
Result
Vapor
1271.4
Lb/hr
Liquid
8728.6
Lb/hr
Estimate amount of 4.0 Kg/cm2G steam that can be generated by flashing 5000 Kg/hr of 10.5 Kg/cm2G
steam condensate available at 180 °C temperature.
- Select Units tab and select units as mentioned above
- Input required data as stated above in Yellow Highlighted Cells
- Calculator will provide following result
Result
Steam
261
Kg/hr
Liquid
4739
Kg/hr